Holds (4) 210 ltr. Drums, 284 L Sump Capacity, 4082 kg Load Capacity
Load your drums into our roomy roll top hardcovers for all-weather protection and liquid containment. You don't even have to remove pumps and funnels!  Read More

PRICING (Based on quantity)

1+
1+
£1,599.00
(Ex. VAT)

Description & Specifications

Load your drums into our roomy roll top hardcovers for all-weather protection and liquid containment. You don't even have to remove pumps and funnels!
  • Roll top slides up for easy access to drum tops whilst the rest of the unit stays closed; store drums with pumps or funnels in place
  • Low-profile pallet with sump catches leaks, drips and spills whilst keeping drum tops and accessories within reach
  • Weather-resistant design prevents contaminants from entering stormwater
  • Heavy-duty construction allows hardcover and pallet to be lifted by a forklift with drums in place
  • Low-density polyethylene (LDPE) with UV inhibitors resists UV rays, rust, corrosion and most chemicals for long, trouble-free life
  • Ergonomically designed roll top only goes down to waist height to eliminate bending and reaching
  • Doors and roll top can be secured with a padlock (sold separately)
  • Durable swing-out doors on front and rear provide easy access from both sides
Dimensions 165cm W x 157cm D x 201cm H
Recycled Content 17% Post-Industrial Recycled Polyethylene
Load Capacity UDL 4082 kg
Sump Capacity 284 L
Access 2 Hinged Doors, 1 Sliding Door
Fork Truck Access 2-way Fork Access
Interior Dimensions 145cm W x 168cm H x 130cm D
Sold as 1 each
Weight 191.52 kg
# per Pallet 1
Composition Pallet & Cover - Low-Density Polyethylene w/ UV Inhibitor
Grate - Injection Molded Polyethylene
Capacity (4) 210 ltr. Drums

Optional Accessories for PAK901

Reviews

Based on 0 review(s)

Additional Information

  • Chemical Compatibility for PIG LDPE Products
  • The Control of Pollution (Oil Storage) Regulations (Northern Ireland) 2010
    The Regulations apply to above ground oil storage facilities on industrial, commercial and institutional residential sites. They also extend to companies who refine or distribute oil. The Regulations set minimum design standards for new and existing above ground oil storage facilities, codifying existing good practice to ensure that above ground oil storage facilities are adequately constructed. A key requirement of the Regulations is for the storage container to have a secondary containment system (a bund, which is an outer wall or enclosure designed to contain the contents of an inner tank, or, a drip tray) to ensure that any leaking or spilt oil is contained and does not enter the aquatic environment.
  • The Control of Pollution (Oil Storage)(England) Regulations 2001
    This regulation applies to any container with a storage capacity of over 200 litres, and applies to any industrial, commercial or institutional site, e.g. factories, shops, offices, hotels, schools, public sector buildings and hospitals. All types of oil except waste oil are included. A bund or catchpit has to form a container around the tank capable of holding 110% of the contents of the oil stored or 25% of the total volume, whichever is greater. This is known as secondary containment.
  • The Water Environment (Oil Storage) (Scotland) Regulations 2006
    This regulation applies to any container with a storage capacity of over 200 litres. It affects all premises, including land and mobile plant, as well as private dwellings. "Oil" means any kind of oil and includes petrol, diesel, waste and vegetable and plant oil, but does not include bitumen. The storage container, whether indoors or outdoors, must be situated within a secondary containment system capable of holding 110% of the contents of the oil store or 25% of the total volume (whichever is greater).
  • The Water Resources (Control of Pollution) (Oil Storage) (Wales) Regulations 2016
    The Regulations apply to any kind of oil, including petrol, diesel, kerosene, lubricating oil (both mineral and synthetic), waste oil, vegetable and plant oil, and apply to any kind of container which has a capacity of greater than 200 litres which is being used to store oil above ground, whether inside or outside a building. This includes fixed tanks, intermediate bulk containers (IBCs), drums (oil drums or similar containers used for storing oil) or mobile bowsers. The Regulations will come into force in 3 stages - Tanks installed after 15 March 2016 will have to comply with the Regulations from the date they are installed; Existing tanks at significant risk (i.e. facilities that are located within 10 metres of any surface water or wetland, or 50 metres of a borehole or well), will have to comply within 2 years (i.e. by 15 March 2018); Existing tanks not at significant risk will have to comply within 4 years (i.e. by 15 March 2020). The secondary containment system must contain at least 110% of the maximum contents of the oil container, or at least 25% of the total storage capacity if multiple containers are stored, whichever is the greater.