PIG® Poly IBC Containment Unit with Bucket Shelf

Holds (1) 1000 ltr. IBC, 1363 L Sump Capacity, 3632 kg Load Capacity
As Low As £1,110.55 (Ex. VAT)
You can't buy a stronger pallet to store your totes in compliance. PIG is the toughest on the market.  Read More

PRICING (Based on quantity)

1 - 2 3 +
1 - 2
£1,169.00
(Ex. VAT)
3 +
£1,110.55
(Ex. VAT)
Best Buy
Best Buy

Description & Specifications

You can't buy a stronger pallet to store your totes in compliance. PIG is the toughest on the market.
  • Strong enough for long-term storage of IBCs, this innovative design transfers weight to load bearing channels to maximise capacity
  • Molded-in sump catches leaks, drips and spills to help you comply with regulations and keep storage areas clean
  • Low-density polyethylene (LDPE) construction resists UV rays, rust, corrosion and most chemicals
  • Textured grating holds a variety of IBC sizes; lifts out for easy access to sump
  • Low profile for easy access to and dispensing from IBC tanks
  • Two-way forklift entry allows movement from either direction when not loaded
  • Attached shelf makes it neater and easier to dispense into 19-litre buckets or smaller containers
  • Mini-sump is bulkheaded to main sump to drain away drips
Dimensions 157cm W x 157cm L x 66cm H
Recycled Content 26% Post-Industrial Recycled Polyethylene
Load Capacity UDL 3632 kg
Sump Capacity 1363 L
Double-Stackable Unit Not Double-Stackable
Drain No Drain
Fork Truck Access Two-Way Fork Access, Move Unloaded Only
Grates (2) 132cm L x 66cm W Grates
Sold as 1 each
Weight 151 kg
# per Pallet 3
Composition Sump - Linear Low-Density Polyethylene w/ UV Inhibitors
Grate - Injection Molded Polyethylene
Capacity (1) 1000 ltr. IBC

Reviews

Based on 0 review(s)

Additional Information

  • Chemical Compatibility for PIG LDPE Products
  • The Control of Pollution (Oil Storage) Regulations (Northern Ireland) 2010
    The Regulations apply to above ground oil storage facilities on industrial, commercial and institutional residential sites. They also extend to companies who refine or distribute oil. The Regulations set minimum design standards for new and existing above ground oil storage facilities, codifying existing good practice to ensure that above ground oil storage facilities are adequately constructed. A key requirement of the Regulations is for the storage container to have a secondary containment system (a bund, which is an outer wall or enclosure designed to contain the contents of an inner tank, or, a drip tray) to ensure that any leaking or spilt oil is contained and does not enter the aquatic environment.
  • The Control of Pollution (Oil Storage)(England) Regulations 2001
    This regulation applies to any container with a storage capacity of over 200 litres, and applies to any industrial, commercial or institutional site, e.g. factories, shops, offices, hotels, schools, public sector buildings and hospitals. All types of oil except waste oil are included. A bund or catchpit has to form a container around the tank capable of holding 110% of the contents of the oil stored or 25% of the total volume, whichever is greater. This is known as secondary containment.
  • The Water Environment (Oil Storage) (Scotland) Regulations 2006
    This regulation applies to any container with a storage capacity of over 200 litres. It affects all premises, including land and mobile plant, as well as private dwellings. "Oil" means any kind of oil and includes petrol, diesel, waste and vegetable and plant oil, but does not include bitumen. The storage container, whether indoors or outdoors, must be situated within a secondary containment system capable of holding 110% of the contents of the oil store or 25% of the total volume (whichever is greater).
  • The Water Resources (Control of Pollution) (Oil Storage) (Wales) Regulations 2016
    The Regulations apply to any kind of oil, including petrol, diesel, kerosene, lubricating oil (both mineral and synthetic), waste oil, vegetable and plant oil, and apply to any kind of container which has a capacity of greater than 200 litres which is being used to store oil above ground, whether inside or outside a building. This includes fixed tanks, intermediate bulk containers (IBCs), drums (oil drums or similar containers used for storing oil) or mobile bowsers. The Regulations will come into force in 3 stages - Tanks installed after 15 March 2016 will have to comply with the Regulations from the date they are installed; Existing tanks at significant risk (i.e. facilities that are located within 10 metres of any surface water or wetland, or 50 metres of a borehole or well), will have to comply within 2 years (i.e. by 15 March 2018); Existing tanks not at significant risk will have to comply within 4 years (i.e. by 15 March 2020). The secondary containment system must contain at least 110% of the maximum contents of the oil container, or at least 25% of the total storage capacity if multiple containers are stored, whichever is the greater.

Disclaimers

Flammables Notice

If using this product with flammable liquids, please consider the regulations that apply to storage and handling of flammable liquids and the safety of this application, specifically flammable vapours, static discharge and heat sources. For further assistance, please call Technical Services.

Poly Pallet - Unloaded Notice

Remove all drums & containers from the pallet before moving.