PIG® Heavy-Duty 2-Drum Poly Spill Containment Pallet

Holds (2) 210 ltr. Steel or Poly Drums, 250 L Sump Capacity, 2041 kg Load Capacity
As Low As £282.15 (Ex. VAT)
The strongest pallets you can buy won't buckle or bow, even under the heaviest loads! Guaranteed for life.  Read More

PRICING (Based on quantity)

1 - 2 3 +
1 - 2
£297.00
(Ex. VAT)
3 +
£282.15
(Ex. VAT)
Best Buy
Best Buy

Description & Specifications

The strongest pallets you can buy won't buckle or bow, even under the heaviest loads! Guaranteed for life.
  • The strongest, most durable containment pallets you can buy won't buckle or bow. We guarantee it.
  • Strong enough for long-term storage of liquids with high specific gravities
  • Innovative design transfers weight to load-bearing channels to maximise capacity
  • Molded-in sump catches leaks, drips and spills to help you comply with regulations and keep your storage areas clean and safe
  • Low height means loading and unloading require less effort and drum tops are within easier reach
  • Low-density polyethylene (LDPE) construction resists UV rays, rust, corrosion and most chemicals
  • Textured grating adds traction and lifts out for easy sump access
  • 2-way forklift entry allows easy movement from either direction (loaded or unloaded)
  • Choose black sidewalls to hide grime; choose translucent white sidewalls for easy visual inspection
  • We test all of our PIG Containment Pallet designs at max load for months to ensure they can handle full capacity at your facility
Dimensions 102cm W x 168cm L x 22cm H
Recycled Content 38% Post-Industrial Recycled Polyethylene
Load Capacity UDL 2041 kg
Sump Capacity 250 L
Double-Stackable Unit Not Double-Stackable
Drain No Drain
Fork Truck Access Two-Way Fork Access, Can Move Loaded
Grates (1) 132cm L x 66cm W Grate
Sold as 1 each
Weight 36.3 kg
# per Pallet 8
Composition Sump - Linear Low-Density Polyethylene w/ UV Inhibitors
Grate - Injection-Molded Polyethylene Foam
Capacity (2) 210 ltr. Steel or Poly Drums

Optional Accessories for PAK604

Reviews

Based on 0 review(s)

Additional Information

  • Chemical Compatibility for PIG LDPE Products
  • The Control of Pollution (Oil Storage) Regulations (Northern Ireland) 2010
    The Regulations apply to above ground oil storage facilities on industrial, commercial and institutional residential sites. They also extend to companies who refine or distribute oil. The Regulations set minimum design standards for new and existing above ground oil storage facilities, codifying existing good practice to ensure that above ground oil storage facilities are adequately constructed. A key requirement of the Regulations is for the storage container to have a secondary containment system (a bund, which is an outer wall or enclosure designed to contain the contents of an inner tank, or, a drip tray) to ensure that any leaking or spilt oil is contained and does not enter the aquatic environment.
  • The Control of Pollution (Oil Storage)(England) Regulations 2001
    This regulation applies to any container with a storage capacity of over 200 litres, and applies to any industrial, commercial or institutional site, e.g. factories, shops, offices, hotels, schools, public sector buildings and hospitals. All types of oil except waste oil are included. A bund or catchpit has to form a container around the tank capable of holding 110% of the contents of the oil stored or 25% of the total volume, whichever is greater. This is known as secondary containment.
  • The Water Environment (Oil Storage) (Scotland) Regulations 2006
    This regulation applies to any container with a storage capacity of over 200 litres. It affects all premises, including land and mobile plant, as well as private dwellings. "Oil" means any kind of oil and includes petrol, diesel, waste and vegetable and plant oil, but does not include bitumen. The storage container, whether indoors or outdoors, must be situated within a secondary containment system capable of holding 110% of the contents of the oil store or 25% of the total volume (whichever is greater).
  • The Water Resources (Control of Pollution) (Oil Storage) (Wales) Regulations 2016
    The Regulations apply to any kind of oil, including petrol, diesel, kerosene, lubricating oil (both mineral and synthetic), waste oil, vegetable and plant oil, and apply to any kind of container which has a capacity of greater than 200 litres which is being used to store oil above ground, whether inside or outside a building. This includes fixed tanks, intermediate bulk containers (IBCs), drums (oil drums or similar containers used for storing oil) or mobile bowsers. The Regulations will come into force in 3 stages - Tanks installed after 15 March 2016 will have to comply with the Regulations from the date they are installed; Existing tanks at significant risk (i.e. facilities that are located within 10 metres of any surface water or wetland, or 50 metres of a borehole or well), will have to comply within 2 years (i.e. by 15 March 2018); Existing tanks not at significant risk will have to comply within 4 years (i.e. by 15 March 2020). The secondary containment system must contain at least 110% of the maximum contents of the oil container, or at least 25% of the total storage capacity if multiple containers are stored, whichever is the greater.

Disclaimers

Flammables Notice

If using this product with flammable liquids, please consider the regulations that apply to storage and handling of flammable liquids and the safety of this application, specifically flammable vapours, static discharge and heat sources. For further assistance, please call Technical Services.